Q.1.
Which of these is NOT true for systematic errors?
Q.2.
It is required to measure angular position. Out of the transducers Circular potentiometerLVDTE pick upSynchro The proper devices are
Q.3.
In two wattmeter method of 3 phase power measurement, when does one wattmeter read negative
Q.4.
Loss of charge method is suitable for medium resistances.
Q.5.
A dynamometer wattmeter is connected in ac circuit. The measured power is
Q.6.
Induction wattmeter can be used in
Q.7.
A moving iron instrument gives correct reading when used at
Q.8.
In a thermocouple temperature transducer, the output voltage is usually measured by
Q.9.
Which of the following statement is correct for two wattmeters method of power measurement in 3 phase circuit?
Q.10.
Which of the following measurements using a dc potentiometer do not require standardisation of potentiometer?
Q.11.
A voltmeter using thermocouples measures
Q.12.
The speed transducer using a drag cup rotor has the main advantage of
Q.13.
A dynamometer wattmeter is connected in ac circuit. The reading will be
Q.14.
A digital frequency counter can be converted to DVM by addition of a suitable
Q.15.
Which of the following are needed both for protection and metering?
Q.16.
Which of the following is true about an impulse voltage?
Q.17.
Assertion (A): A hot wire ammeter has a cramped scale.Reason (R): The heat is proportional to square of current.
Q.18.
Potentiometer method of dc voltage measurement is more accurate than direct measurement using a voltmeter because
Q.19.
A moving coil instrument has a resistance of 0.5 Ω and a full scale deflection of 0.1 A. To convert it into an ammeter of 0-A the shunt resistance should be
Q.20.
A standard cell of 1.V is used with a slide wire potentiometer. The balance was obtained atcm. When an unknown emf was connected, the balance was obtained atcm. The magnitude of unknown emf is
Q.21.
In a resistance strain gauge, G =stress =kg/cmR =Ω. The value of ΔR will be
Q.22.
A meter with a resistance ofΩ and a full scale deflection of current of 1 mA is to be converted into voltmeter of 0 - 5 V range. The multiplier resistance should be
Q.23.
Magnetic flux density has the dimensions
Q.24.
The angle δ for a mica capacitor is about
Q.25.
The Lissajous pattern observed on screen of CRO is a straight line inclined atto x axis. If X-plate input is 2 sin ωt, the Y-plate input is
Q.26.
A digital voltmeter has a read out range from 0 tocounts. If the full scale reading is 9.V, the resolution is
Q.27.
Consider the following statements: In a differential amplifier using JFET, the differential output offset is due to mismatch between FET parametersdifference in values of resistances used in circuitvariation in supply voltage. Of the statements, the correct statements are
Q.28.
The coil of a moving coil meter hasturns, ismm long andmm wide. The control torque isx 10-6 N-m on full scale. If B = 1 Wb/mrange of meter is
Q.29.
In a strain measuring device using a strain gauge, the output quantity is
Q.30.
Two resistors R1 =Ω ±and R2 =Ω ±are connected in series. The total resistance is