Q.1.

An induction wattmeter can be used for ac only.

Q.2.

Loading effect is primarily caused by instruments having

Q.3.

Capacitive transducer is superior to inductive type for measurement of capacitance because of

Q.4.

In Weston synchronoscope the fixed coils are connected across

Q.5.

Which of the following is not a transducer in true sense?

Q.6.

Which of the following can be used for measuring capacitance?

Q.7.

Consider the following statements about mutual inductances:

  1. The value should remain constant under all conditions.
  2. The mutual inductance should not vary with temperature.
  3. The inductance should be independent of excitation.
  4. They have two coils wound on a bobbin of hard magnetic material, coils being separated by a range.
Out of the above, correct statement are
Q.8.

The total insulation resistance consists of insulation volume resistance and surface leakage resistance.

Q.9.

Assertion (A): Energy meters use induction principle.

Reason (R): Induction wattmeter is less accurate than a dynamometer wattmeter.

Q.10.

The phenomenon of creep occurs in

Q.11.

Magnetic deflection sensitivity is defined as

Q.12.

Which of the following is active transducer?

Q.13.

The dimensions of permittivity are

Q.14.

The sensitivity of a potentiometer can be increased by

Q.15.

The coding system generally used in digital telemetry is

Q.16.

Assertion (A): A dc potentiometer measures the true open circuit emf of a source.

Reason (R): At balance point, a dc potentiometer does not draw any current from the source.

Q.17.

Wagner earthing device is used to eliminate error due to

Q.18.

RTD is generally suitable for temperature up to

Q.19.

The adjustment of position of shading bands, in an energy meter, is done to provide

Q.20.

Shaft encoder is used to measure

Q.21.

Assertion (A): Hay's bridge in particularly suitable for measuring inductance having a comparatively low resistance.

Reason (R): In Hay's bridge the value of frequency supply must be known.

Q.22.

To measure a resistance of about 8 ohms we should use

Q.23.

Which of the following effects is used in measurement of magnetic flux?

Q.24.

The range of RTD using platinum is about

Q.25.

To avoid the effect of stray magnetic fields in ac bridge we can use

Q.26.

The resistance of voltmeter affects the accuracy of measurement in loss of charge method.

Q.27.

Assertion (A): In a CRT, grid is kept at negative potential with respect to cathode.

Reason (R): The function of grid in an electronic tube is to control the number of electrons.

Q.28.

A dynamometer wattmeter can be used for

Q.29.

A D' Arsonval galvanometer is a

Q.30.

Assertion (A): When frequencies of signals fed to X and Y plates of CRO are multiples of each other, Lissajous pattern is displayed on screen.

Reason (R): In a CRO, the vertical deflection is proportional to voltage applied to Y plates.

Q.31.

The device having highest photo sensitivity is

Q.32.

Which of the following closely represents the resistance-temperature characteristics of thermistor?

Q.33.

Consider the following statements regarding electro-dynamometer type indicating instrument
It can be used for measuring

  1. Direct current
  2. Alternating current
  3. Direct voltage
  4. Alternating voltage
Of these statements
Q.34.

Which of these instruments has highest power consumption?

Q.35.

For measuring temperatures below 800°C with high accuracy, the best instrument is

Q.36.

Panel instruments are generally mounted vertically.

Q.37.

A digital voltmeter has a 4 1/2 digit display. The 1 V range can measure voltage up to

Q.38.

Consider the following statements as regards induction and dynamometer wattmeters

  1. Dynamometer wattmeters can be used for dc only.
  2. Induction wattmeter has higher torque and dynamometer wattmeter.
  3. Induction wattmeter is less accurate, has more power consumption and more weight than dynamometer wattmeter.
Which of the above statements are correct?
Q.39.

A resistance strain gauge is usually

Q.40.

In a hot wire instrument, the deflection is proportional to

Q.41.

Schering bridge is used to measure

Q.42.

A power factor meter has

Q.43.

In portable instruments, damping is provided by

Q.44.

If A =± 8 and B =±A - B with range of doubt is

Q.45.

Assertion (A): Many instruments use eddy current damping.

Reason (R): Eddy currents set up a magnetic flux which opposes the original movement which generates them.

Q.46.

A Maxwell's bridge has the unknown inductance in one arm and resistance in the other three arms.

Q.47.

Assertion (A): Secondary instruments require calibration at frequent intervals.

Reason (R): Secondary instruments have many errors.

Q.48.

A permanent magnet moving coil meter can be used as

Q.49.

Assertion (A): In a CRT, grid is kept at negative potential with respect to cathode.

Reason (R): The function of grid in an electronic tube is to control the number of electrons.

Q.50.

In a semiconductor strain gauge, the ohmic electrical contacts are generally made of