Q.1.

For use atHz the range of scale of vibrating reed frequency meter is

Q.2.

A current of 3.A is flowing through a resistance of 34.Ω. The voltage drop across resistance to the appropriate number of significant figures is

Q.3.

Assertion (A): An RTD uses platinum coil.

Reason (R): Platinum is a very stable material.

Q.4.

Which of the following, is not a piezoelectric material?

Q.5.

Assertion (A): In two wattmeter method of 3 phase power measurement, one of the wattmeters would read negative if power factor of load is less than 0.5.

Reason (R): In two wattmeter method of 3 phase power measurement, both the wattmeters would show equal readings if power factor of load is unity.

Q.6.

In a low power factor wattmeter, the resistance of pressure coil is more than in ordinary wattmeter.

Q.7.

The precision of an instrument indicates its ability to reproduce a certain reading with a given

Q.8.

Assertion (A): A radiation pyrometer is very suitable for high temperature measurement.

Reason (R): When temperature is high, a physical contact between hot body and thermometer is not desirable.

Q.9.

A universal RLC bridge uses

Q.10.

If φsh is flux of shunt magnet, φse is flux of series magnet, ish is eddy current due to φse, the torque in an induction wattmeter is proportional to

Q.11.

In low power factor wattmeter, the compensating coil is connected

Q.12.

When deflecting torque and braking torque in an energy meter are zero,

Q.13.

During testing of an energy meter, the energy recorded by meter was 0.kWh and correct energy was found to be 0.kWh. The error and correction respectively are

Q.14.

Two resistances are : R1 =Ω ± 1.Ω and R2 =Ω ± 3.Ω. The sum R1 + R2 along with limiting error is

Q.15.

Consider the following statements about a moving iron instrument

  1. It is an unpolarised instrument.
  2. It has permanent magnet.
  3. It has a fixed coil.
  4. It has two iron vanes.
Of these statements
Q.16.

The braking torque in single phase energy meter is proportional to speed of disc.

Q.17.

To measure a resistance by a dc potentiometer

Q.18.

Harmonic distortion analyser

Q.19.

In a megger the moving coil meter has a permanent magnet.

Q.20.

The moving iron instruments are generally repulsion type.

Q.21.

If C is spring constant and θ is deflection, controlling torque is

Q.22.

A generated voltage is equally dependent on three resistances R1, R2, R3 and its value is V = (R1R2)/R3. If tolerance of each resistor is 0.1%, the maximum error in voltage is

Q.23.

The sensitivity of a voltmeter using 0-5 mA meter movement is

Q.24.

An instrument of accuracy class 1 can have an error equal to

Q.25.

The two pressure coils in a single phase power factor meter of turns

Q.26.

Piezoelectric effect can be used to measure

Q.27.

In dc tacho generators used for measurement of speed of shaft, frequent calibration is necessary because

Q.28.

A multimeter can be used as ohmmeter.

Q.29.

Rayleigh current balance is an absolute instrument.

Q.30.

Assertion (A): A thermocouple transducer is based on Seeback effect.

Reason (R): In a thermocouple transducer used for temperature measurement, the cold junction is usually kept in ice bath.

Q.31.

In an Anderson bridge the unknown inductance is measured in terms of

Q.32.

Assertion (A): The scale a PMMC ammeter is linear.

Reason (R): The deflecting torque of PMMC is proportional to current in the coil.

Q.33.

A voltage of aboutV dc can be measured

Q.34.

Assertion (A): If the resistance of shunt of an ammeter is increased, the range of ammeter is reduced.

Reason (R): If the series resistance of a voltmeter is increased, the range of voltmeter is increased.

Q.35.

In figure, C0 is distributed capacitance and C is tuning capacitor. If C = C1 for fundamental frequency and C = C2 for second harmonic, then C0 =

Q.36.

Two meters X and Y requiremA andmA for full scale deflection. Then

Q.37.

A dual trace CRO has

Q.38.

A current of 3.A is flowing through resistance of 35.Ω. The voltage drop across resistance to the appropriate number of significant figures is

Q.39.

Assertion (A): Moving iron instrument can be used on ac or dc.

Reason (R): In a moving iron instrument deflecting torque is proportional to square of current.

Q.40.

In a low power factor wattmeter, compensation for pressure coil current is provided.

Q.41.

Two sinusoidal signals of equal amplitude and frequency are applied to X and Y plate of CRO respectively. The observed Lissajous pattern is a straight line. The phase shift between signals is

Q.42.

For measuring mutual inductance we can use

Q.43.

Which instrument needs creep compensation?

Q.44.

A land line telemetry system is suitable for distance upto

Q.45.

De Sauty bridge is very widely used due to

Q.46.

The scale of a dynamometer is linear when used as

Q.47.

The moving iron instruments are generally repulsion type.

Q.48.

Use of high permeability core in moving iron instrument helps in

Q.49.

The resistance of series field winding is a low resistance.

Q.50.

A Weston synchronoscope is a